HH500 Series Handheld Digital Thermometers
General Specifications
Input Type: Type J or K Thermocouple
Power Supply: Single 9V battery (included)
Battery Life: 200 hours
Dimensions: 192 (H) × 91 (W) × 53 mm (D) (7.6 × 3.6 × 2.2")
Weight: Approx. 255 g (9 oz)
HH501AJK Digital Thermometer
Single-channel digital thermometer, 1999-count resolution, backlit LCD, Type J/K thermocouple input, display hold and Max function. ITS-90 Accuracy: ±0.2%.
Display Type: Backlit LCD
Max Count: 1999
Input Channels: 1
Temperature Range: -50 ~ 1370°C (-58 ~ 1950°F)
Resolution: 0.1° / 1°
Display Screens: 1
Supplied with: 1 × bead wire Type K thermocouple
Basic Accuracy: ±(0.1% of reading + 1°C)
HH501BJK Digital Thermometer
Dual Type J/K thermocouple input, 1999-count resolution, backlit LCD, display hold, Max function, T1-T2 differential measurement.
Display Type: Backlit LCD
Max Count: 1999
Input Channels: 2
Temperature Range: -50 ~ 1370°C (-58 ~ 1950°F)
Resolution: 0.1° / 1°
Display Screens: 1
Supplied with: 2 × bead wire Type K thermocouples
Basic Accuracy: ±(0.1% of reading + 1°C)
HH502 Digital Thermometer
Dual Type J/K thermocouple input, 25,000-count resolution, Min/Max memory, T1-T2 differential measurement. ITS-90 Accuracy: ±0.05%.
Display Type: LCD
Max Count: 25,000
Input Channels: 2
Temperature Range: -200 ~ 1370°C (-328 ~ 2498°F)
Resolution: 0.1°
Display Screens: 3
Supplied with: 2 × bead wire Type K thermocouples
Basic Accuracy: ±(0.05% of reading + 0.3°C)
HH503 Digital Thermometer
Type J/K thermocouple input, 25,000-count resolution, Min/Max, Average, Relative and Hold functions. ITS-90 Accuracy: ±0.05%.
Display Type: LCD
Max Count: 25,000
Input Channels: 1
Temperature Range: -200 ~ 1370°C (-328 ~ 2498°F)
Resolution: 0.1°
Display Screens: 3
Supplied with: 1 × bead wire Type K thermocouple
Basic Accuracy: ±(0.05% of reading + 0.3°C)
Model & Accessory List
| Part Number | Description |
|---|
| HH501AJK | Single Input Thermometer, Type J or K Thermocouple Input |
| HH501BJK | Dual Input Thermometer, Type J or K Thermocouple Input |
| HH502 | Dual Input Thermometer, Type J or K Input; Audible Alarm, High/Low Limit & Time Setting Functions |
| HH503 | Single Input Thermometer, Type J or K Input; Audible Alarm, High/Low Limit & Time Setting Functions |
| SC-HH500 | Soft Carrying Case for HH500 Series |
| HH-MAG | Magnetic Strap for Rubber Protective Boot |
| KTSS-HH | 6" Long, 1.8" Diameter Stainless Steel Type K Probe, 12" Retractable Cable (extendable to 48") with Miniature Connector |
| HH-NIST | NIST Traceable Certificate Without Data Points |
| CAL-3-HH | NIST Traceable Certificate With Data Points |
| MN1604 | Spare 9V Battery |
Note: Standard package includes rubber protective boot with tilt stand, 9V alkaline battery and operation manual. Thermometer models include 1 or 2 bead wire thermocouples (one per channel).
Order Examples:
HH501AJK, Single Input Handheld Thermometer for Type J or K Thermocouples.
HH501BJK, Dual Input Handheld Thermometer for Type J or K Thermocouples.