CL950A temperature probe calibrator
Product Introduction:
CL900A-220 dry-block temperature probe calibrator, with RS232 communication interface, 230Vac power supply, temperature range: ambient +22 to 482°C CL950A-220 dry-block temperature probe calibrator, with RS232 communication interface, interchangeable inserts, multi-port CL950A-M-220 dry-block temperature probe calibrator, with RS232 communication interface, interchangeable inserts, metric, multi-port, 230Vac power supply- Consultation Hotline:18615230752 Landline:0531-88975421
Product Details
Technical parameters
Application scenarios
Optional accessories
Contact Us
CL900A-220 dry-block temperature probe calibrator, with RS232 communication interface, 230Vac power supply, temperature range: ambient +22 to 482°C
CL950A-220 dry-block temperature probe calibrator, with RS232 communication interface, interchangeable inserts, multi-port
CL950A-M-220 dry-block temperature probe calibrator, with RS232 communication interface, interchangeable inserts, metric, multi-port, 230Vac power supply
[CL900A/CL950A Dry-Block Furnace, Temperature Probe Calibrator — Features]
Dry-block temperature probe calibrator with RS-232 communication
Calibrate thermistors, thermocouples, and RTDs in minutes
High accuracy ±0.8°C (±1.5°F) and excellent stability ±0.2°C (±0.3°F) for precision calibration
Portable, rugged design
Wide temperature range from ambient +22 to 482°C (ambient +40 to 900°F). Covers most industrial applications
NIST-traceable CAL certificate includes three data points
CE-marked model
RS-232 standard
Companion Ice Point™ reference cell, model TRCIII-A
The CL900A/CL950A dry-block furnace, temperature probe calibrator is part of a new series of calibrators that quickly and easily calibrate thermistors, thermocouples, and RTD probes with an accuracy of ±0.8°C (±1.5°F). The integrated RTD sensor ensures high measurement accuracy and repeatability. The built-in microprocessor-based PID digital controller ensures excellent stability. Setpoint and actual temperature are displayed simultaneously. Temperature can be set in one-degree increments from ambient +22 to 482°C (ambient +40 to 900°F).
The CL900A/CL950A dry-block furnace, temperature probe calibrator accepts a variety of optional inserts, available in 4" and 6" depths with probe diameters from 1/8" to 3/8". Undrilled inserts are also available. The CL900A includes a 1/4" diameter, 6" deep insertion hole and insert removal clamp as standard. Other inserts for other diameter probes can be ordered separately as required. The 6" depth insert is for probes 7" and longer. The 4" depth insert is for probes 5" and longer.

186-1523-0752
0531-88975421